---
product_id: 48419983
title: "2 Port 22mm or 28mm Motorised Zone Valve Head Can Replace Honeywell V4043H1056 V4043H1106 V4043C1156 V4043H1007  V4043H1080"
brand: "honeywell"
price: "FREE"
currency: EUR
in_stock: false
reviews_count: 8
url: https://www.desertcart.sk/products/48419983-2-port-22mm-or-28mm-motorised-zone-valve-head-can
store_origin: SK
region: Slovakia
---

# No plumbing or draining needed Fits 22mm & 28mm pipes 2-port motorised valve head 2 Port 22mm or 28mm Motorised Zone Valve Head Can Replace Honeywell V4043H1056 V4043H1106 V4043C1156 V4043H1007  V4043H1080

**Brand:** honeywell
**Price:** FREE
**Availability:** ❌ Out of Stock

## Summary

> ⚡ Upgrade your heating game—smart, simple, and stress-free!

## Quick Answers

- **What is this?** 2 Port 22mm or 28mm Motorised Zone Valve Head Can Replace Honeywell V4043H1056 V4043H1106 V4043C1156 V4043H1007  V4043H1080 by honeywell
- **How much does it cost?** FREE with free shipping
- **Is it available?** Currently out of stock
- **Where can I buy it?** [www.desertcart.sk](https://www.desertcart.sk/products/48419983-2-port-22mm-or-28mm-motorised-zone-valve-head-can)

## Best For

- honeywell enthusiasts

## Why This Product

- Trusted honeywell brand quality
- Free international shipping included
- Worldwide delivery with tracking
- 15-day hassle-free returns

## Key Features

- • **Effortless DIY Upgrade:** Replace your Honeywell valve head in minutes—no plumber required.
- • **Trusted Industry Standard:** Direct replacement for multiple Honeywell models with matching wiring colors.
- • **Universal Fit Flexibility:** Compatible with 22mm and 28mm pipes for seamless integration.
- • **Zero Downtime Installation:** No need to drain your heating system—keep your home warm uninterrupted.
- • **Built to Last with Warranty:** 3-year guarantee ensures peace of mind and long-term reliability.

## Overview

This 2-port motorised zone valve head is a direct, hassle-free replacement for popular Honeywell models, fitting both 22mm and 28mm pipes. Designed for easy DIY installation without draining your central heating system, it features standard wiring colors and a 3-year guarantee, making it the go-to choice for efficient, reliable heating control upgrades.

## Description

2 Port 22mm or 28mm Motorised Zone Valve Head Can Replace Honeywell V4043H1056 This unit is a direct replacement for the following installed with a longer guarantee Honeywell V4043H1056 Honeywell V4073H1106 Honeywell V4043C1156 Honeywell V4043H1007 Honeywell V4043H1080 Honeywell 272848 Honeywell motorised valves made before 1987 will also require a 40003918-006 conversion kit. Valves made after 1987 can be identified by a bump on the top of the powerhead British gas no. 378452 Banico Tower Horstmann Save on the large cost of plumbing, and fitting a new 2 port valve; just replace the head This head has the same design, dimensions and cable colours as the Honeywell Two Port Head Fits 22 or 28mm Switch Rating 3Amp 3 Year Guarantee 240 Volt Supply Manual Lever Override Valve Normally Closed Common Cable Colours Brown - Live Orange - End Switch Out Grey - End Switch In Blue - Neutral Green/Yellow - Earth Bullets change to: 2 Port 22mm or 28mm Motorised Zone Valve Head Replace Honeywell V4043H1056 V4043H1106 V4043C1156 V4043H1007 V4043H1080 Simple Swap over , no expensive plumbing required DIY Fit , common cable colours

Review: Excellent product - This works exactly as you would expect. It is cheaper than most and mine has been working for a couple of months now without problem. It fitted onto a standard Honeywell valve just replacing the old actuator. Just changing the head means you do not have to interfere with the water pipes at all and makes it a relatively easy job. Just put the two actuators to the manual position before changing so the valve stem is in the correct position relative to the actuator when fitting. If you do have a problem with a valve actuator and it is on the heating you can leave it in the open position which means you get heating when your water is on but that is not a serious problem in the winter till you can get a new actuator. The timer controls will still control the boiler coming on and off.
Review: Fully compatible with 'industry standard brand' as stated, well-designed, great product - I swapped out (yet another!) dead 'Honeybad' valve with no problems whatsoever. Functions well. Looks like it will last as well as, if not longer, than the original. It is physically and electrically compatible with the 'Honeybad' product (the cheap gear mechanism is what usually fails in those - terrible design IMO). Note: get a qualified electrician to do the job! Buy hey... tips: **** Note: Do this at your own risk - get a qualified Electrician to install, check etc. !!!! SAFETY: ALL POWER OFF FIRST!!! Swap out the old for new, matching colour coding of wires. Take a picture first, to show original wiring! If the connection point has poor access, or is just crammed with other wiring, consider adding a 'flying lead' box to ease changing over valves: - The lead on old, inoperative valve was cut near the valve, stripped, and rewired into a... - Honeyw*ll terminal box (2 x 6way terminal blocks - so enough for 2nd valve when it fails!) - The new valve was then wired into the terminal box, like-wire to like-wire. This leaves the original, more complex wiring box, untouched. This is especially advisable if you have several zone values in addition to a hotwater valve. On a previous failure, the original terminals were crammed on my system and it was very difficult to remove individual wires and then try and insert new ones, whilst keeping other wires in place! **** Reminder: Do this at your own risk - get a qualified Electrician to install, check etc. !!!! :) Other tips: I found no problems - but do DOUBLE-check the connections - including INSIDE the valve - especially the Earth!! Don't cover the valves - they get hot as it is. Use minimum force to manually operate the valves - that mechanism is the weakest part of the design (both old and new)! Enjoy!

## Features

- 2 ports with 22 and 28 mm; motorised zone valve disc
- Easy to change; no extensive piping required
- No need to drain water from the central heating system, suitable for self-installation
- UK Gas Number 378452
- International products have separate terms, are sold from abroad and may differ from local products, including fit, age ratings, and language of product, labeling or instructions.

## Technical Specifications

| Specification | Value |
|---------------|-------|
| ASIN | B00BAI2NMO |
| Best Sellers Rank | 118,166 in DIY & Tools ( See Top 100 in DIY & Tools ) 934 in Central Heating System Accessories 3,595 in Bathroom Fixtures |
| Brand | Honeywell |
| Connector Type | Threaded |
| Customer Reviews | 4.3 out of 5 stars 652 Reviews |
| Exterior Finish | Brass |
| Exterior finish | Brass |
| Inlet Connection Size | 22 Millimeters |
| Inlet Connection Type | 22mm or 28mm |
| Inlet connection size | 22 Millimeters |
| Inlet connection type | 22mm or 28mm |
| Manufacturer | Honeywell, Tower, Horstmann |
| Material | Brass |
| Model Number | V4043H1056 |
| Number of Pieces | 1 |
| Number of Ports | 2 |
| Outlet Connection Size | 22 Millimeters |
| Outlet Connection Type | BSPT |
| Outlet connection type | BSPT |
| Part Number | FTB375 |
| Set Name | Honeywell |
| Size | 22mm or 28mm |
| Smart Home Compatibility | Not Smart Home Compatible |
| Specification Met | British Gas Number 378452 |
| Thread Size | 22mm or 28mm |
| Thread Type | BSP |
| Unit Count | 1.0 count |
| Valve Type | zone_valve |

## Product Details

- **Brand:** Honeywell
- **Exterior finish:** Brass
- **Inlet connection size:** 22 Millimeters
- **Inlet connection type:** 22mm or 28mm
- **Manufacturer:** Honeywell, Tower, Horstmann
- **Material:** Brass
- **Number of ports:** 2
- **Outlet connection size:** 22 Millimeters
- **Outlet connection type:** BSPT
- **Specification met:** British Gas Number 378452

## Images

![2 Port 22mm or 28mm Motorised Zone Valve Head Can Replace Honeywell V4043H1056 V4043H1106 V4043C1156 V4043H1007  V4043H1080 - Image 1](https://m.media-amazon.com/images/I/61oyMHZCBhL.jpg)
![2 Port 22mm or 28mm Motorised Zone Valve Head Can Replace Honeywell V4043H1056 V4043H1106 V4043C1156 V4043H1007  V4043H1080 - Image 2](https://m.media-amazon.com/images/I/61xOHV30ScL.jpg)
![2 Port 22mm or 28mm Motorised Zone Valve Head Can Replace Honeywell V4043H1056 V4043H1106 V4043C1156 V4043H1007  V4043H1080 - Image 3](https://m.media-amazon.com/images/I/71AbYuJjVRL.jpg)

## Questions & Answers

**Q: can this fit a replcement honey well number 8846(this was also a replacement head some years ago**
A: We can't find any reference to Honeywell 8846 - as this was a replacement head are you sure that's the Honeywell number?

**Q: can this work with honeywell V4043h1106 28 mm fitting?**
A: It replaces the powerhead element of the valve, so should (I am not a plumber!) work with V4043H1056 (28mm fitting) or V4043H1106 (22 mm fitting)

**Q: is this the DVA2/5 siemens item**
A: The DVA2/5 is the replacement actuator for Siemens CVZ valves.(It is also OK for Orkli and Telford models) It is doubtful if this head, which is designed for Honeywell valves, would fit a Siemens CVZ valve

**Q: Can this directly replace a Horstmann F222m? That is just pull off the Horstmann and replace it without any plumbing needing done?**
A: Yes!!!   You must ensure that the control is set to manual and just simply remove. The converse applies, ensure the control is set to manual and replace over the valve. No plumbing is required.

## Customer Reviews

### ⭐⭐⭐⭐⭐ Excellent product
*by D***D on 23 April 2014*

This works exactly as you would expect. It is cheaper than most and mine has been working for a couple of months now without problem. It fitted onto a standard Honeywell valve just replacing the old actuator. Just changing the head means you do not have to interfere with the water pipes at all and makes it a relatively easy job. Just put the two actuators to the manual position before changing so the valve stem is in the correct position relative to the actuator when fitting. If you do have a problem with a valve actuator and it is on the heating you can leave it in the open position which means you get heating when your water is on but that is not a serious problem in the winter till you can get a new actuator. The timer controls will still control the boiler coming on and off.

### ⭐⭐⭐⭐⭐ Fully compatible with 'industry standard brand' as stated, well-designed, great product
*by K***W on 2 December 2018*

I swapped out (yet another!) dead 'Honeybad' valve with no problems whatsoever. Functions well. Looks like it will last as well as, if not longer, than the original. It is physically and electrically compatible with the 'Honeybad' product (the cheap gear mechanism is what usually fails in those - terrible design IMO). Note: get a qualified electrician to do the job! Buy hey... tips: **** Note: Do this at your own risk - get a qualified Electrician to install, check etc. !!!! SAFETY: ALL POWER OFF FIRST!!! Swap out the old for new, matching colour coding of wires. Take a picture first, to show original wiring! If the connection point has poor access, or is just crammed with other wiring, consider adding a 'flying lead' box to ease changing over valves: - The lead on old, inoperative valve was cut near the valve, stripped, and rewired into a... - Honeyw*ll terminal box (2 x 6way terminal blocks - so enough for 2nd valve when it fails!) - The new valve was then wired into the terminal box, like-wire to like-wire. This leaves the original, more complex wiring box, untouched. This is especially advisable if you have several zone values in addition to a hotwater valve. On a previous failure, the original terminals were crammed on my system and it was very difficult to remove individual wires and then try and insert new ones, whilst keeping other wires in place! **** Reminder: Do this at your own risk - get a qualified Electrician to install, check etc. !!!! :) Other tips: I found no problems - but do DOUBLE-check the connections - including INSIDE the valve - especially the Earth!! Don't cover the valves - they get hot as it is. Use minimum force to manually operate the valves - that mechanism is the weakest part of the design (both old and new)! Enjoy!

### ⭐⭐⭐⭐ Works well and easy installation
*by J***N on 17 November 2025*

installed straightforward to replace the honeywell original one. Works well so far. But will update review on how long it can last!

## Frequently Bought Together

- 2 Port 22mm or 28mm Motorised Zone Valve Head Can Replace Honeywell V4043H1056 V4043H1106 V4043C1156 V4043H1007  V4043H1080
- Team Controls Replacement Universal Synchronous Synchron Motor for Honeywell or Drayton Motorised Valves TC-SYN
- Replacement Synchronous Motor for Motorised Valves ACL Honeywell Landis Gye Satchwell Sopec Tower Replacement Part 2-Port 3-Port Valve Failure

---

## Why Shop on Desertcart?

- 🛒 **Trusted by 1.3+ Million Shoppers** — Serving international shoppers since 2016
- 🌍 **Shop Globally** — Access 737+ million products across 21 categories
- 💰 **No Hidden Fees** — All customs, duties, and taxes included in the price
- 🔄 **15-Day Free Returns** — Hassle-free returns (30 days for PRO members)
- 🔒 **Secure Payments** — Trusted payment options with buyer protection
- ⭐ **TrustPilot Rated 4.5/5** — Based on 8,000+ happy customer reviews

**Shop now:** [https://www.desertcart.sk/products/48419983-2-port-22mm-or-28mm-motorised-zone-valve-head-can](https://www.desertcart.sk/products/48419983-2-port-22mm-or-28mm-motorised-zone-valve-head-can)

---

*Product available on Desertcart Slovakia*
*Store origin: SK*
*Last updated: 2026-09-21*