🔥 Keep Your Pool Perfectly Heated!
The Optimum Pool Technologies 42001-0063S High Limit Switch Replacement is designed for Pentair MasterTemp and Max-E-Therm heaters, ensuring safe operation at a maximum temperature of 135°F. This reliable replacement part is compatible with all MasterTemp models and select Max-E-Therm models, making it an essential upgrade for pool maintenance enthusiasts.
A**2
Easy DIY repair job for HLS error on your heater
My Pentair 400,000 Btu pool heater stopped running and gave me the "Service Heater" light on the control panel. The indicator light on the backside of the panel showed "HLS", meaning a problem with the High Level Switch part. After following the diagnostic tree in the manual (i.e. I knew I didn't have excessively hot water coming out as the heater never fired up) it was clear that the switch had gone bad. A few online videos showed that getting into the heater was pretty simple and replacing the sensor was a straight forward job. This switch proved a perfect "drop in" replacement for the original and, after a trip to the hardware store, I had my pool heater back in business.You can see the pictures for why I had to make a run to the store. The teeth on the outside of the sensor are for the wire clamps to slip on and make the connection. My original sensor's teeth had rusted so badly that they came apart when I tried to unplug and I could get the broken teeth out. Took the new sensor with me so I could test out and buy the right size connectors as I only wanted to make this drive one time. An 18mm wrench is the right size for removing/reinstalling the senor.Save yourself from the high prices of the pool store or an expensive repair call - this one is an easy DIY repair.
D**B
Great Quality - But...
If you're buying this due to the Diagnostic LED on your Pentair stating it's the High Limit Switch, there is a very good possibility that it is actually a corroded Thermal Regulator, also located in the Manifold. My heater would heat on and off and was taking a long time to heat my spa. LED indicated it was the HLS. Bought this to replace, but heater still had the same issue and LED indicator. After exhaustive internet searches, I located lots of info stating that this issue is commonly due to a corroded Thermal Regulator. Sure enough, replacing it solved my problem and heater runs great now.
J**R
DANGER, DANGER, DANGER: Out of Specification!!!
Danger: I just received two of these High Limit Switches from Amazon, and I tested them against Pentair's specification of 135 Deg. F for switching the pool heater off. They both failed to operate until dangerously high temperatures. One operated at 147.5 Deg. F, and the other operated at 145.3 Deg. F. Note that 3rd degree burns are near instantaneous if skin comes in contact with 145 Degree water. I believe Amazon should immediately suspend sales of this item, and Amazon and the manufacturer (a company call Optimum, NOT Pentair) should issue a recall of these devices, and contact the Consumer Product Safety Commission. This is a critical part of the safety system for the Pentair pool heater. I have access to laboratory grade thermal test equipment, including digital thermometers and a precision circulating water bath that I used in the testing. Each unit was tested multiple times, and the results were essentially identical. Most customers would not do this testing, and would think there were being protected by this switch. They would not be protected.
R**1
STA RITE spa heater
Quick shipping. Part was exact replacement to my STA RITE spa heater temp sensor. Unfortunately, it did not resolve my issue.
J**B
Excellent.
Worked perfectly. Even came with the tape dope already in place. Just had to Screw out the old + screw in the new.
E**E
Perfect replacement!
Excellent replacement. Worked very well for my Temp400
T**.
Works well
Working exactly as it should, no issues.
R**O
Lasted only a Year
Only lasted one season before it needed to be replaced. Going to splurge on OEM so I don't have to replace annually.